POLON 6000 - Distributed architecture main panel

The POLON 6000 fire alarm control panel is designed to detect and signal fire hazard after receiving information from the detectors and manual call points cooperating with it. The control panel coordinates the operation of all devices in the system and makes a decision on initiating a fire alarm, controlling signalling and fire protection devices and transmitting information to the monitoring centre or surveillance system. The POLON 6000 control panel is recommended for fire protection of various types of facilities, especially large ones, e.g. hotels, office buildings, warehouses, historic buildings, "intelligent" buildings with a large number of cooperating fire automation devices. It can be easily integrated into many existing facility security management systems on the market. The control panel meets the requirements of PN-EN 54-2 and PN-EN 54-4 standards.

Application

The POLON 6000 fire alarm control panel is designed to detect and signal a fire hazard after receiving information from the detectors and manual call points cooperating with it. The control panel coordinates the operation of all devices in the system and makes a decision on initiating a fire alarm, controlling signalling and fire protection devices and transmitting information to the monitoring centre or surveillance system.

The POLON 6000 control panel is recommended for fire protection of various types of facilities, especially large or extensive ones, e.g. hotels, office buildings, warehouses, historic buildings, “intelligent” buildings with a large number of cooperating fire automation devices. It can be easily integrated into many existing facility security management systems on the market.

Design and functionality

The POLON 6000 fire alarm control panel has been designed on concept of a modular device with a distributed architecture. It consists of many unified modules of various types, placed in standard frames, which, individually or combined in sets (the so-called nodes), can be placed in various points of the protected facility, even at a considerable distance from each other. All modules within a single node and nodes between each other are connected by a common, double (redundant) digital communication bus.

The control panel is a scalable device – it can be freely combined from modules and nodes in quantities tailored to the individual needs of the facility, and then expanded, if necessary, with other enclosures with equipment. Such a solution allows the necessary optimization the control panel equipment installed in places where it is necessary, and thus to reduce the installation costs, while ensuring very high reliability of the system. This is ensured by the use of duplicate processor controllers, communication buses, and cable connections between nodes.

The POLON 6000 control panel consists of PSO-60 control panels with a 10″ touch display, functional modules: MLD-61 and MLD-62 detection lines, MKS-60 control lines, MPK-60 relay outputs, MWS-60 potential outputs, MPW-61 high-voltage relay outputs, MWK-60 control inputs, MZP-60 power supply, MD-60 printer module and MTI-61, MTI-62, MTI-63 transmission modules. Control panels and modules are mounted in standard-sized enclosures, which can be mechanically connected to each other to form two-, three- or multiple enclosures. Mechanically connected frames form the node of the control panel. The control panel must have at least one node in which the main control panel PSO-60 number 1 is mounted. It is so called main node of the control panel and only one can be fixed in the installation. The rest of the control panel equipment consists of the so-called elevated nodes, which must be connected to the main node of the control panel.

Communication between nodes is carried out by means of a duplicated cable connection (RS-485) or a duplicated pair of optical fibers. Each node should be equipped with a power supply module. In each node of the control panel the line modules can be applied. to which detection lines and input/output elements for direct control of fire automation devices can be connected to the line modules Each elevated node can be equipped with a PSO-60 control panel that acts as an additional remote operator panel

Specification:
  • Supply voltage (main) 230 V
  • Supply voltage (standby) 2 pcs. 12 V od 17 Ah do 134 Ah
  • Number of detection lines in the system 396
  • Max. loop current 50 mA
  • Maximum number of point detectors on a loop line 250 - POLON 6000 protocol;

    127 - POLON 4000 protocol
  • Maximum number of point detectors in the linear line 32
  • Number of alarming variants 15
  • Number of detection zones 99 000
  • Number ofconventional detection lines in the system 792
  • Signaling lines (potential) 600
  • potential-free relay outputs 1000
  • Number of detection lines 1200
  • Maximum number of modules 1089
  • Maximum number of a given type of modules 99
  • Operating temperature range from -10 °C up to +40 °C
Name File type File name File size Download
Data Sheet Polon 6000 Documentation of products withdrawn from production POLON-6000-1.pdf 871.51 KB
POLON 6000 Installation and Maintenance Manual Installation and Maintenance Manual ID-E332-001GB-ed.-IF-POLON6000-1.pdf 6.25 MB
POLON 6000 certificate Certificates POLON-6000-Cert-CPR_2-1.pdf 5.16 MB
POLON 6000 UAE Certificate Certificates POLON-6000_UAE-1.pdf 3.44 MB
Response Instruction POLON6000 Documentation of products withdrawn from production response-instructions-POLON-6000.pdf 254.34 KB
POLON 6000 calculator Software Tools Authorised users only 773.38 KB
POLON 6000 Info sheet Marketing materials Folders POLON-6000-Info-sheet.pdf 1.22 MB
POLON 6000 Distributed fire alarm system Marketing materials Folders POLON-6000-Distributed-fire-alarm-system.pdf 1.67 MB
POLON 6000 System overview Marketing materials Folders POLON-6000-System-overview.pdf 1.58 MB
POLON 6000 Certificate of Conformity Certificates POLON_6000_0049_2024_certyfikate_of_conformity_EN_54-13.pdf 13.6 MB
POLON 6000 Declaration of Conformity Declaration of Conformity POLON_6000_DZ_UE_1_E332_2024.pdf 2.36 MB
POLON 6000 Declaration of Performance Declaration of Performance POLON_6000_DWU_1_E332_2024.pdf 7.78 MB
PolonStudioSetup_1.4.0 Software Authorised users only 27.03 MB