UCS 6000 from 16A up to 32A - Universal control panel

The UCS 6000 universal control panel is designed for actuation of fire protection devices, used for mechanical or gravitation smoke ventilation (fire dampers, smoke exhaust dampers etc.) and enables the following:

The UCS 6000 universal control panel is designed to activate fire-fighting devices used for gravitational and mechanical smoke extraction (smoke ventilation dampers, shut-off dampers) the control panel enables:

  • Fire (smoke) detection;
  • Activation of fire-fighting devices installed in smoke extraction systems (automatic or manual)
  • Accoustic and optical device operating states signalling (alarm, fault);
  • Automatic control of fire protection and actuators (actuators, electromagnets, fans, etc.) of the smoke extraction system;
  • Automatic conduct of the control panel’s own systems and circuits;
  • Providing basic information to main control panels (e.g. POLON 4000 system, POLON 6000 system, IGNIS 1000 system or others) regarding alarms, faults, condition of fire protection and actuator equipment.

The UCS 6000 control panel can operate individually as a single or multi-zone universal smoke extraction controller or in addressable detection lines/loops of the POLON 4000 and POLON 6000 system fire alarm control panels.

Control panel modules:

MGS-60 module

  • a supervised line receiving the alarm signal from an external fire alarm control panel,
  • a rain and/or wind sensor supply line,
  • a rain and/or wind sensor signal receiving line,
  • the supervised PKA alarm relay (continuity of wire), the PKU fault relay.

MGL-60 Module

  • conventional detector line (40 model range detectors),
  • conventional line for manual smoke exhaust call points ( PO-6X model range manual call points),
  • Control and supply universal supervised main output for fire protection devices (servomotors of fire/smoke dampers, electromagnets of fire zones separators, etc.),
  • Status of limit switches control lines of fire protection devices controlled and powered by the main output,
  • lines receiving signals from ventilation push buttons (OPEN, CLOSE);

MPW-60 Module:

  • PK1 and PK2 high voltage type programmable relays (5 A/ 230 V)
  • LK1 and LK2 supervised programmable monitoring lines (24 V) ;

MPD-60 module:

  • PK1 and PK2 supervised, programmable relays (1 A / 24 V),
  • LK1 and LK2 supervised programmable monitoring lines (24 V);

MKA-60 Module :

  • POLON 4000 communication line (addressable detector line);

MZU-60 Module:

  • PKUZ – supply fault relay (1 A / 24 V)
  • External devices supply supervised output (0.5 A / 24 V).
Specification:
  • Supply voltage (main) 230 V
  • Supply voltage (standby) from 7,2 Ah up to 65 Ah
  • Operating temperature range -10 °C to +55 °C
Name File type File name File size Download
UCS 6000 Datasheet Datasheets UCS-6000.pdf 776.59 KB
UCS 6000 Installation and Maintenance Manual Installation and Maintenance Manual UCS-6000-IMM_ENG.pdf 3.4 MB
UCS 6000 Certificate of Constancy of Performance Certificates UCS-6000_CPR-wyd_2_3-1.pdf 428.25 KB
UCS 6000 Configurator Software Tools Authorised users only 28.25 MB
UCS 6000 Declaration of Performance Declaration of Performance UCS-6000_DWU_01_E345_2022-1.pdf 534.2 KB
UCS 6000 Declaration of Conformity Declaration of Conformity UCS_6000_Deklaracja-zgodnosci_UE_1_E345_2017.pdf 441.77 KB