UCS 6000 from 32A up to 64A - Universal control panel

The UCS 6000 universal control panel is designed for actuation of fire protection devices, used for mechanical or gravitation smoke ventilation (fire dampers, smoke exhaust dampers etc.) and enables the following:

The UCS 6000 universal control panel is designed to activate fire-fighting devices used for gravitational and mechanical smoke extraction (smoke ventilation dampers, shut-off dampers) and enables:

  • Fire (smoke) detection;
  • Activation of fire-fighting devices installed in smoke extraction systems (automatic or manual)
  • Accoustic and optical device operating states signalling (alarm, fault);
  • Automatic control of fire protection and actuators (actuators, electromagnets, fans, etc.) of the smoke extraction system;
  • Automatic conduct of the control panel’s own systems and circuits;
  • Providing basic information to main control panels (e.g. POLON 4000 , POLON 6000, POLON 3000, IGNIS 1000  or others) regarding alarms, faults, condition of fire protection and actuator equipment.

The UCS 6000 control panel can operate individually as a single or multi-zone universal smoke extraction controller or in addressable detection lines/loops of the POLON 4000 and POLON 6000 system fire alarm control panels.

Control panel modules:

MGS-60 module

  • a supervised line receiving the alarm signal from an external fire alarm control panel,
  • a rain and/or wind sensor supply line,
  • a rain and/or wind sensor signal receiving line,
  • the supervised PKA alarm relay (continuity of wire), the PKU fault relay.

MGL-60 Module

  • conventional detector line (40 model range detectors),
  • conventional line for manual smoke exhaust call points ( PO-6X model range manual call points),
  • Control and supply universal supervised main output for fire protection devices (servomotors of fire/smoke dampers, electromagnets of fire zones separators, etc.),
  • Status of limit switches control lines of fire protection devices controlled and powered by the main output,
  • lines receiving signals from ventilation push buttons (OPEN, CLOSE);

MPW-60 Module:

  • PK1 and PK2 high voltage type programmable relays (5 A/ 230 V)
  • 2 supervised programmable LK1 and LK2 (24 V) monitoring lines;

MPD-60 module:

  • 2 supervised, programmable relays PK1 and PK2 (1 A / 24 V),
  • 2 supervised programmable LK1 and LK2 (24 V) monitoring lines;

MKA-60 Module :

  • POLON 4000 communication line (addressable detector line);

MZU-60 Module:

  • supply fault relay – PKUZ (1 A / 24 V)
  • External devices supply supervised output (0.5 A / 24 V).
specifikáció:
  • Supply voltage (main) 230 V
  • Supply voltage (standby) from 7,2 Ah up to 65 Ah
  • Operating temperature range -10 °C to +55 °C